Veuillez vous connecter pour utiliser cette fonctionnalité.
Contactez votre distributeur local :
Téléphone : +1 850 650 7790
The store will not work correctly when cookies are disabled.
Menu
Account
Chromatography
Affinity Chromatography
HyperChrom SP HP Agarose
HyperChrom SP HP Agarose
Skip to the end of the images gallery
Skip to the beginning of the images gallery
Featured Products
mRNA synthesis
In vitro transcription of capped mRNA with modified nucleotides and Poly(A) tail
Tyramide Signal Amplification (TSA)
TSA (Tyramide Signal Amplification), used for signal amplification of ISH, IHC and IC etc.
Phos Binding Reagent Acrylamide
Separation of phosphorylated and non-phosphorylated proteins without phospho-specific antibody
Cell Counting Kit-8 (CCK-8)
A convenient and sensitive way for cell proliferation assay and cytotoxicity assay
Inhibitor Cocktails
Protect the integrity of proteins from multiple proteases and phosphatases for different applications.
Description
HyperChrom SP HP Agarose is a strong cation exchange chromatography medium that separates molecules using differences in charge properties and amounts under specific conditions. The chromatography medium can be well used for the isolation and purification of a variety of biomolecules, such as: recombinant proteins, antibodies, nucleic acids, viruses and virus-like particles, polysaccharides, etc.
HyperChrom SP HP Agarose has excellent scale-up performance: (1) Highly crosslinked agarose base with excellent rigidity, so high process flow rates and improved process efficiency at low back pressure. (2) Through chemical modification, it has excellent chemical compatibility and is resistant to CIP cleaning such as sodium hydroxide. (3) Fine particle size design to improve resolution.
HyperChrom SP HP Agarose chromatography media parameters
Name
Description
Chromatography media type
Strong cation exchange
Ligation
- (CH2)3SO3- (sulfopropyl).
Scaffolding
Highly cross-linked agarose
Average particle size
34 μm
Ion load
0.15-0.20 mmol H+ /mL chromatography medium
Dynamic load
>50 mg β-lactoglobulin/mL chromatography medium*
Flow rates are recommended
90-150 cm/h
Maximum flow rate
200 cm/h
Withstand pressure
0.3 MPa
Use temperature
4-30℃
pH stability **
2-14
Solvent resistant
Common aqueous solution, 30% isopropanol***, 75% ethanol***, 1 M NaOH, 1 M acetic acid, 6 M guanidine hydrochloride, 8 M urea
Intolerant to solvents
Oxidant, cationic detergent
*Dynamic load measurement conditions: column loading height: 10 cm, test flow rate 150 cm/h, test buffer: 0.1 M Citrate solution, pH 8.0, test sample: 4 mg/m Lβ-lactoglobulin sample, when the penetration of β-lactoglobulin reaches 10%,β-lactoglobulin loading volume per unit media volume (mL) (mg).
**After 7 days of storage of chromatography medium at 40°C and pH 2-14, its physicochemical properties and functions did not change significantly.