Alpha-ketoglutaRate-dependent Dioxygenase FTO (FTO) BioAssay™ ELISA Kit (Human)

Referencia 587347-96Tests

embalaje : 96Tests

Marca : US Biological

Solicitar más información

Contact local distributor :


Teléfono : +1 850 650 7790


587347 Alpha-ketoglutaRate-dependent Dioxygenase FTO (FTO) BioAssay™ ELISA Kit (Human)

Clone Type
Polyclonal
Swiss Prot
Q9C0B1
Shipping Temp
Blue Ice
Storage Temp
4°C/-20°C

For quantitative detection of FTO in human serum, plasma and other biological fluids. Cell lysates and tissue homogenates, though not tested, may potentially be used as samples.||Detection Range:|0.156-10ng/ml||Sensitivity: |0.094ng/ml||Precision: |Intra-Assay %CV: <8% |Inter-Assay %CV: <10% ||Specificity:|This assay has high sensitivity and excellent specificity for detection of FTO. No significant cross-reactivity or interference between FTO and analogues was observed.||Assay Principle:|This BioAssay™ kit was based on sandwich enzyme-linked immune-sorbent assay technology. Capture antibody was pre-coated onto 96-well plates. And the biotin conjugated antibody was used as detection antibodies. The standards, test samples and biotin conjugated detection antibody were added to the wells subsequently, and washed with wash buffer. HRP-Streptavidin was added and unbound conjugates were washed away with wash buffer. TMB substrates were used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the target amount of sample captured in plate. Read the O.D. absorbance at 450nm in a microplate reader, and then the concentration of target can be calculated.||Kit Components:|Microtiter Strips, 1x96 wells|Standard, 2x1 vial|Sample/Standard Dilution Buffer, 1x20ml|Antibody (Biotin) (Concentrated), 1x60ul|Antibody Dilution Buffer, 1x10ml|Streptavidin (HRP) (SABC), 1x120ul|SABC Dilution Buffer, 1x10ml|TMB Substrate, 1x10ml|Wash Buffer, 25X, 1x30ml||Storage and Stability:|Store unopened Microtiter Strips at 4ºC; store at -20ºC once opened. Store unopened Standard at 4°C; once reconstituted, store at 4°C for up to 12 hours or at -20°C for up to 48 hours. Store other components at 4°C. Kit is stable for 6 months after receipt. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.

Applications
Important Note: This product as supplied is intended for research use only, not for use in human, therapeutic or diagnostic applications without the expressed written authorization of United States Biological.