Pyruvate Dehydrogenase Beta (PDHb) BioAssay™ ELISA Kit (Human)
Referencia 517604-96T
embalaje : 96Tests
Marca : US Biological
517604 Pyruvate Dehydrogenase Beta (PDHb) BioAssay™ ELISA Kit (Human)
Clone Type
PolyclonalSwiss Prot
P11177Shipping Temp
Blue IceStorage Temp
4°C/-20°CSample Type:|Tissue homogenates, cell lysates, cell culture supernates and other biological fluids||Intended Use:|The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PDHb in human tissue homogenates, cell lysates, cell culture supernates and other biological fluids.||Sensitivity:|0.65ng/ml||Range:|1.56-100ng/ml||Specificity:|This assay has high sensitivity and excellent specificity for detection of Pyruvate Dehydrogenase Beta (PDHb). No significant cross-reactivity or interference between Pyruvate Dehydrogenase Beta (PDHb) and analogues was observed.||Precision:|Intra-Assay: CV<10% |Inter-Assay: CV<12%||Test Principle:|The microplate provided in this kit has been pre-coated with an antibody specific to PDHb. Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to PDHb. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain PDHb, biotin-conjugated antibody and|enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of PDHb in the samples is then determined by comparing the O.D. of the samples to the standard curve.||Kit Components:|96-well strip plate, 1x Plate |Standard, 2x vial|Detection Reagent A, 1×120ul|Detection Reagent B, 1×120ul|TMB Substrate, 1×9ml|Wash Buffer (30X), 1×20ml|Standard Diluent, 1×20ml|Assay Diluent A, 1×12ml|Assay Diluent B, 1×12ml|Stop Solution, 1x6ml||Storage and Stability:|Store microtiter strips, Standard, Detection Reagent A, Detection Reagent B and positive control at -20°C. After reconstitution of the postive control store at 4°C and use within 5 days. Store all the other components at 4°C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.