EnzyChrom™ Succinate Assay Kit

Referencia ESNT-100

embalaje : 100tests

Marca : BioAssay Systems

Solicitar más información

Contact local distributor :


Teléfono : +1 850 650 7790

EnzyChrom™ Succinate Assay Kit



Application

  • For quantitative determination of succinate (succinic acid) in food, beverage, agricultural products, and other biological samples.

Key Features

  • Fast and sensitive. Use a 20 µL sample. Linear detection range from 10 to 400 µM for colorimetric assays and 2 to 40 µM for fluorimetric assays.
  • Convenient. The procedure involves adding a single working reagent and reading the absorbance or fluorescence after 30 minutes. Room temperature assay. No 37°C heater is needed.
  • High-throughput. Can be readily automated as a high-throughput 96-well plate assay for thousands of samples per day.

Method

  • OD570nm, FL530/585nm

Samples

  • succinate in food, beverage, agricultural products, and other biological samples

Species

  • All

Procedure

  • 30 min

Size

  • 100 tests

Detection Limit

  • Colorimetric assay: 10 µM; Fluorimetric assay: 2 µM

Shelf Life

  • 6 months

More Details

SUCCINATE, or succinic acid, can be found in all plants and animal tissues. It is an intermediate in the citric acid cycle and plays an important role in intracellular energy generation. Succinate is widely used as a flavoring agent in the food, beverage, and pharmaceutical industries due to its low toxicity.BioAssay Systems′ succinate assay provides a simple, one-step assay for measuring succinate. In this assay, succinate is converted to pyruvate which reacts with specific reagents and dye to form a colored product. The color intensity at 570 nm or fluorescence at Fex/em = 530/585 nm of the reaction product is directly proportional to the succinate concentration in the sample.

Does the assay kit work in particular species? And what samples have you tested?

Yes, our assays work in all species. We have tested in red wine, soy sauce and urine samples.

I don’t have the correct wavelength filter, will the assay still work?

Typically if you are within ±20 nm the assay will still work, but have slightly reduced sensitivity. Some assays have a narrower peak than others, call our tech support for a spectrum to verify.

I don’t have a 96-well plate, will the assay kit work in a 384 well plate, cuvette, etc?

Yes, the assay can be used in any standard plate and cuvette. Simply adjust the total reaction volume to your container. For 384 well use 50 µL, use a narrow cuvette for 500 µL.

How do I prepare cell or tissue samples for assays?

Cell Samples. Suspend about two million (2 x 106) harvested cells in 400 µL PBS on ice. Lysis can be achieved by homogenization (10-20 passes in a Dounce homeginer on ice) or by sonication (preferably performed in an ice-water bath). The degree of cell lysis can be checked under a microscope. Centrifuge homogenate at 14,000 g for 10 min. Transfer the clear supernatant into a clean tube. It is prudent to run a pilot test of the sample at different dilutions. Choose a dilution with the readings in the linear range of the standard curve for further assays. Most samples can be stored at -80°C if not assayed immediately.

Tissue Samples. Start with 20-100 mg tissue, add 200- 1000 µL ice-cold PBS. Lysis can be achieved by homogenization (10-20 passes in a Dounce homeginer on ice) or by sonication (preferably performed in an ice-water bath). The degree of tissue lysis can be checked under a microscope. Centrifuge homogenate at 14,000 g for 10 min. Transfer the clear supernatant into a clean tube. It is prudent to run a pilot test of the sample at different dilutions. Choose a dilution with the readings in the detection range of the standard curve for further assays. Most samples can be stored at -80°C if not assayed immediately.

Urine sample: no dilution necessary for colorimetric assays; 1:10 in H2O for fluorimetric assays.

Can I store unused reagents for future use?

Yes, unused reagents can be stored according to the assay protocol. Repeated freeze/thaw cycles of reagents should be avoided.

Do I need to use a standard or standard curve with each assay run?

Yes, standard curve should be performed with each fluorimetric assay run. Internal standard should be included with each colorimetric assay run.

Ceperuelo-Mallafre, V et al (2019). Preoperative circulating succinate levels as a biomarker for diabetes remission after bariatric surgery. Diabetes Care, 42(10), 1956-1965. Assay: Succinate in human serum.

Astiarraga, B et al (2020). Impaired succinate response to a mixed meal in obesity and type 2 diabetes is normalized after metabolic surgery. Diabetes Care, 43(10), 2581-2587. Assay: Succinate in human plasma.

Serena, C., Ceperuelo-Mallafre, V., Keiran, N., Queipo-Ortuno, M. I., Bernal, R., Gomez-Huelgas, R., & Moya, A. (2018). Elevated circulating levels of succinate in human obesity are linked to specific gut microbiota. The ISME journal, 12(7), 1642. Assay: Succinate in human serum.

To find more recent publications, please click here.

If you or your labs do not have the equipment or scientists necessary to run this assay, BioAssay Systems can perform the service for you.

– Fast turnaround
– Quality data
– Low cost

Succinate Assay Kit
Catalog No: ESNT-100 Categories Agriculture & Environment, Blood & Urine Chemistry, Diabetes & Obesity, Food & Beverage Analysis, Metabolism Tags Agriculture & Environment, Blood & Urine Chemistry, Diabetes & Obesity, EnzyChrom Succinate Assay Kits, EnzyChromTM Succinate Assay Kit, ESNT-100, Food & Beverage Analysis, metabolism, Succinate assay kits, Succinate determination kits, Succinate measurement kits, Succinate test kits

Usted podría estar interesado también en los siguientes productos:



Referencia
Descripción
Cond.
Precio Sin IVA