Fluorescent TrueBlot®: Anti-Rabbit IgG DyLight™ 800

Referência 18-4516-32

Tamanho : 100ul

Marca : Rockland Immunochemicals

Solicitar mais informações

Contactar o distribuidor local :


Telefone : +1 850 650 7790

Specifications for Fluorescent TrueBlot®: Anti-Rabbit IgG DyLight™ 800

Product Details

Fluorescent TrueBlot®: Anti-Rabbit IgG DyLight™ 800 - 18-4516-32
Anti-Rabbit IgG DL800, TrueBlot, DL800 TrueBlot ULTRA, DyLight™ 800 TrueBlot, TrueBlot for IP/WB, TrueBlot for immunoprecipitation, TrueBlot for western blotting, Fluorescent TrueBlot, Rb TrueBlot, Infrared, IR, NIR, IR800
Mouse
DyLight™ 800
Monoclonal
IgG

Target Details

Rabbit
Fluorescent Rabbit TrueBlot® Antibody DyLight™ 800 Conjugate was prepared from tissue culture supernatant by Protein G affinity chromatography. Assay by Immunoelectrophoresis resulted in a single precipitin arc against Anti-Rabbit Serum. Reactivity is observed against native Rabbit IgG by both Western blot and ELISA.

Application Details

Dot Blot, IP, WB
Fluorescent Rabbit TrueBlot® Antibody DyLight™ 800 has been tested in dot blot, western blot, and immunoprecipitation and may also be used for detection in immunoassays that do not employ immunoprecipitation. Fluorescent Rabbit TrueBlot® Antibody DyLight™ 800 is provided as a lyophilized powder. To conserve reagent, we recommend incubating the blots from minigels in sealed bags (removing as much air as possible) with minimal volume (2-3 mLs). If used conservatively at 2.5mLs/blot will yield enough reagent for 200 blots. Note that there are three key procedural considerations: 1. Protein A or G should not be used for the immunoprecipitation. Use of protein A or G beads with the rabbit TrueBlot will result in contaminating bands. For immunoprecipitation, Anti-rat IgG beads, or Anti-rabbit IgG beads should be used for rat or rabbit immunoprecipitating antibodies, respectively. 2. Immunoprecipitate should be completely reduced. 3. Bovine Serum Albumin, or MB-070 Blocking Buffer for Fluorescent Western Blotting, at low concentrations, should be used as the blocking protein for the immunoblot. DO NOT USE BLOTTO or MILK. All recommended dilutions for listed applications are intended as an initial recommendation, specific conditions for each protein and antibody combination should be specifically optimized by the end user. Fluorescence technology is widely used to detect proteins. However, many common visible fluorophores often result in considerable background fluorescence in the visible range. Visible fluorophores are rarely used for membrane-based protein detection because of this high background. DyLight™ 800 and DyLight™ 680 antibody and reagent conjugates are specifically designed for protein detection methods that use longer-wavelength, near-infrared (IR) fluorophores to visualize proteins in western blotting and other applications. Very low background fluorescence in the IR range provides for a much higher signal-to-noise ratio than visible fluorophores. Detection levels in the picogram range on Western blots rival the sensitivity of chemiluminescence on film. DyLight™ 800 conjugates are optimized for the Odyssey® Infrared Imaging System developed by LI-COR. DyLight™ 800 conjugates are also suitable for immunofluorescence microscopy using commercially available excitation/emission filters in the 780nm/820nm range. Dual simultaneous labeling in western blots or microscopy is achieved when DyLight™ 800 conjugates are used in conjunction with DyLight™ 680 conjugates. DyLight™ 800 and DyLight™ 680 conjugates provide an ultra-sensitive and convenient alternative to standard chemiluminescent protein detection methods, as well as a valuable tool for multicolor imaging.

Formulation

1.0 mg/mL by UV absorbance at 280 nm
0.02 M Potassium Phosphate, 0.15 M Sodium Chloride, pH 7.2
0.01% (w/v) Sodium Azide
10 mg/ml Polyethylene Glycol (PEG-8000)
100 µL
Restore with deionized water (or equivalent)

Shipping & Handling

Ambient
Store vial at 4 °C prior to restoration. For extended storage aliquot contents and freeze at -20 °C or below. Avoid cycles of freezing and thawing. Centrifuge product if not completely clear after standing at room temperature. This product is stable for several weeks at 4 °C as an undiluted liquid. Dilute only prior to immediate use.
Expiration date is one (1) year from date of receipt.

Background

Rabbit IgG TrueBlot® is a unique DyLight™ 800 conjugated Anti-rabbit IgG monoclonal secondary antibody. Rabbit IgG TrueBlot® enables detection of immunoblotted target protein bands, without hindrance by interfering immunoprecipitating immunoglobulin heavy and light chains. It is easy to generate publication-quality IP/Fluorescent Western Blot data with Rabbit IgG TrueBlot®, simply substitute the conventional DL800 Anti-rabbit IgG blotting reagent with Fluorescent Rabbit TrueBlot® Antibody DyLight™ 800 and follow the prescribed protocol for sample preparation and immunoblotting. Ideal for Li Cor Odyssey imaging as well as other IR and near IR imaging systems. Rabbit IgG TrueBlot® is ideal for use in protocols involving immunoblotting of immunoprecipitated proteins. TrueBlot preferentially detects the non-reduced form of rabbit IgG over the reduced, SDS-denatured form of IgG. When the immunoprecipitate is fully reduced immediately prior to SDS-gel electrophoresis, reactivity of Rabbit IgG TrueBlot® with the 55 kDa heavy chains and the 23 kDa light chains of the immunoprecipitating antibody is minimized thereby eliminating interference by the heavy and light chains of the immunoprecipitating antibody in IP/Western blot applications. Applications include studies examining post-translational modification (e.g., phosphorylation or acetylation) or protein-protein interactions.

References (7)

(). Mammalian hybrid pre-autophagosomal structure HyPAS generates autophagosomes. Cell.
Applications
Undefined
PubMed
(). Long non-coding RNA ASB16-AS1 enhances cell proliferation, migration and invasion via functioning as a ceRNA through miR-1305/Wnt/β-catenin axis in cervical cancer. Biomed Pharmacother.
Applications
WB, IB, PCA
PubMed
(). Interaction between the autophagy protein Beclin 1 and Na+,K+-ATPase during starvation, exercise, and ischemia. JCI insight
Applications
IP, Co-IP
PubMed
(). Phosphorylation of Syntaxin 17 by TBK1 Controls Autophagy Initiation. Dev Cell.
Applications
Undefined
PubMed
(). A Metabolic Basis for Endothelial-to-Mesenchymal Transition. Molecular Cell
Applications
IP, Co-IP; WB, IB, PCA
PubMed
(). Identification and validation of the role of matrix metalloproteinase-1 in cervical cancer. International Journal of Oncology
Applications
WB, IB, PCA
PubMed
(). The role of ZKSCAN3 in the transcriptional regulation of autophagy. Autophagy
Applications
IP, Co-IP
PubMed

Frequently Asked Questions (13)

What is Rockland’s TrueBlot® product line?

Rockland’s TrueBlot® product line is designed to solve common experimental problems when performing immunoprecipitation/co-immunoprecipitation experiments and Western blots of immunoprecipitated samples (IP–Western blot). The product line consists of TrueBlot® monoclonal secondary antibodies and TrueBlot® IP beads.

What is the advantage of TrueBlot® secondaries over regular secondary antibodies?

TrueBlot® antibodies are specific to the whole IgG molecule and will not bind heavy or light chains. This is useful for binding target proteins with an expected MW near 25 kDa (light chains) and 50 kDa (heavy chains).

Why does it appear that the TrueBlot® antibody is binding heavy/light chains in my sample?

The sample must be fully reduced to eliminate cross-reactivity with heavy and light chains. Any reactivity to heavy and light chains could be due to incomplete reduction of your sample. Please be sure to optimize reducing conditions for your sample type.

How can I ensure my samples are fully reduced?

Samples can be fully reduced by heating at 90-100°C for 10 minutes in sample buffer containing reducing agent (for example, DTT to a final concentration of 50 mM or add β-Mercaptoethanol to a final concentration of 2% (v/v)).

With which species/isotypes are TrueBlot® secondary antibodies reactive?

TrueBlot® secondary antibodies are reactive with the IgG of their respective species. For example, if using a primary antibody raised in mouse (mouse host), use TrueBlot® anti-mouse Ig secondary antibodies for detection.

Do TrueBlot® secondary antibodies detect IgM?

TrueBlot® secondary antibodies have not been shown to detect IgM.

Do I need to preclear my lysate before the immunoprecipitation step?

Samples that have many other proteins present (such as lysates) may require preclearing to prevent interference in later IP and WB procedures. Recombinant protein samples require pre-clearing more often than serum samples.

How can I enrich/concentrate my lysate for a low expression of a protein of interest?

The immunoprecipitation procedure can be repeated several times to yield a more concentrated protein solution.

What is the recommended lysis buffer for TrueBlot® products?

The optimal lysis buffer will depend on your sample type. See protocol for buffer recommendations. Generally, 1X RIPA is used to lyse samples.

My target protein has the same MW as a heavy/light chain. How can I be sure that the band is the target protein and not a heavy/light chain?

Be sure to include a positive control for the primary antibody in your experiment and check that the sample is fully reduced.

What is the average size of TrueBlot® magnetic/agarose beads?

The beads are roughly 0.5 μm in diameter.

Why can’t I use Protein A or Protein G beads for the IP step in IP–Western blot when using rabbit species?

Using Protein A or Protein G beads with rabbit species results in contaminated bands. For best results when using rabbit species, use Rockland’s TrueBlot® Rabbit Ig IP beads, which are available in either a magnetic or agarose format. Please see individual TrueBlot® Rabbit product pages for additional details.

Can I use Protein A or Protein G beads for the IP step in IP–Western blot when using mouse, goat, or sheep species?

Yes. If you are using Protein A or Protein G beads with mouse, goat, or sheep species, we recommend the following: Determine the compatibility of Protein A or Protein G with your species and subtype, do not use excessive amounts of slurry, and choose the appropriate elution conditions. In some instances, harsher elution conditions can cause stripping of the subunits of Protein A or Protein G from the bead support and result in non-specific bands. For best results, we recommend using TrueBlot® Ig IP beads, which are available in either agarose or magnetic format.

Related Protocols

Adherent Cell Lysis Protocol
Fluorescent Western Blotting Protocol
General Immunoblotting Protocol
Histone Immunoblotting Protocol
Immunoprecipitation (IP) Protocol
In-Cell Western (ICW) Protocol
IP-WB with TrueBlot® Protocol
Multi-Lysate Western Blotting Protocol
Nuclear & Cytoplasmic Extract Protocol
Suspension Cultured Cell Lysis Protocol
Western Blotting (WB) Protocol

Certificate of Analysis Lookup

Invalid lot number

Search

If you need help finding your CoA, contact us

Disclaimer

This product is for research use only and is not intended for therapeutic or diagnostic applications. Please contact a technical service representative for more information. All products of animal origin manufactured by Rockland Immunochemicals are derived from starting materials of North American origin. Collection was performed in United States Department of Agriculture (USDA) inspected facilities and all materials have been inspected and certified to be free of disease and suitable for exportation. All properties listed are typical characteristics and are not specifications. All suggestions and data are offered in good faith but without guarantee as conditions and methods of use of our products are beyond our control. All claims must be made within 30 days following the date of delivery. The prospective user must determine the suitability of our materials before adopting them on a commercial scale. Suggested uses of our products are not recommendations to use our products in violation of any patent or as a license under any patent of Rockland Immunochemicals, Inc. If you require a commercial license to use this material and do not have one, then return this material, unopened to: Rockland Inc., P.O. BOX 5199, Limerick, Pennsylvania, USA.

Related products to: Fluorescent TrueBlot®: Anti-Rabbit IgG DyLight™ 800

Related Resources

Você também pode estar interessado nos seguintes produtos:



Referência
Descrição
Cond.
Price Bef. VAT
MBS762971-96
 96-Strip-Wells